Mea Hoʻolako Lapaʻau ʻOihana

13 Makahiki Hana Hana
  • info@medke.com
  • 86-755-23463462

Nā mea hoʻohana nānā maʻi

  • Nihon Kohden IBP Cable I PVB Transducer B0609

    Nihon Kohden IBP Cable I PVB Transducer B0609

    Medke P/N: B0609 Nihon Kohden IBP uwea i ka PVB transducer Latex free 3m TPU uwea Eono mahina palapala palapala CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Nihon Kohden: Lifescope 6,9,12,14;AP-311P-800PA BMS 2100-8500A OEC 3200-8120A, OMP-3221E OMP-7203C, Mercury 9510K Nā kikoʻī Palekana: IEC 60101-1 i ʻae ʻia, kūlike me ka MDD 93/42/EEC a me ka mahana o ka AAMI00/42/EEC 40°C(32 a i 104°F) Ka haʻahaʻa haʻahaʻa: 15% a 95% Materi...
  • Kontron IBP Cable I Medex/Abbott Transducer B0408

    Kontron IBP Cable I Medex/Abbott Transducer B0408

    Medke P/N: B0408 Kontron IBP uwea i Medex/Abbott transducer Latex free 3m TPU uwea Eono mahina palapala palapala CE/ISO 13485 FSC FDA Nā pūʻolo: non-sterilization, pūʻolo pākahi me ke aʻo Compatibility Kontron: Minimon, Fetalmon Fetalogic Supermon Specifications Palekana: IEC 60101-1 apono 'ia, conformity me MDD 93/42/EEC a me AAMI/ANSI SP10 Ambient wela: 0 i 40 ° C(32 a hiki i 104 ° F) pili humidity: 15% a 95% Mea: Quality TPU jacket cable;ʻO ka lāʻau lapaʻau PVC hoʻomaha;Ke kala gula...
  • GE Marquette IBP Uila I Medex/Abbott Transducer B0407

    GE Marquette IBP Uila I Medex/Abbott Transducer B0407

    Medke P/N: B0407 GE Marquette IBP uwea i Medex/Abbott transducer Latex free 3m TPU uwea Eono mahina palapala palapala CE/ISO 13485 FSC FDA Nā pūʻolo: non-sterilization, pākahi pākahi me ke aʻo Compatibility GE-Marquette: Dash1000, 2000, 2000, 4000, Solar 8000, 9000 Nā kikoʻī Palekana: IEC 60101-1 i ʻae ʻia, kūlike me MDD 93/42/EEC a me AAMI/ANSI SP10 ʻO ka mahana wela: 0 a i 40 ° C(32 a 104 ° F) Ka haʻahaʻa pili: 15% a 95 % Nā mea waiwai: ʻO ke kaula lole TPU maikaʻi;Lapaʻau PVC stra...
  • GE-Datex IBP Uila I Medex/Abbott Transducer B0406

    GE-Datex IBP Uila I Medex/Abbott Transducer B0406

    Medke P/N: B0406 GE-Datex IBP Cable To Medex/Abbott Transducer Latex free 3m TPU cable ʻEono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Nā pūʻolo: non-sterilization, pākahi pākahi me ke aʻo Compatibility GE-Datex: NDE, PB, Nellcor , Tektronix, Viatek Specifications Palekana: IEC 60101-1 i'āponoʻia, kūlike me MDD 93/42 / EEC a me AAMI / ANSI SP10 Ka wela wela: 0 a hiki i 40 ° C(32 a 104 ° F) Hoʻohālikelike pili: 15% a 95% Mea : Uea lole lole TPU maikai;ʻO ka lāʻau lapaʻau PVC hoʻomaha;gula pl...
  • Ua kūpono ʻo Drager-Siemens IBP no ka transducer Medex/Abbott, B0404

    Ua kūpono ʻo Drager-Siemens IBP no ka transducer Medex/Abbott, B0404

    Medke P/N: B0404 Drager-Siemens IBP Adapter Hose, kūpono no ka Medex/Abbott transducer Latex free 3m TPU cable ʻEono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Drager-Siemens:Sirecust 400 -1281, SC8000 Nā kikoʻī Palekana: IEC 60101-1 i ʻae ʻia, kūlike me ka MDD 93/42/EEC a me AAMI/ANSI SP10 ʻO ka mahana wela: 0 a 40 ° C(32 a 104 ° F) Ka haʻahaʻa pili: 15% a 95% Mea : Uea lole TPU maikai;Lapaʻau PVC kānana re...
  • Ua kūpono ʻo Drager-Siemens IBP no ka transducer Medex/Abbott, B0403

    Ua kūpono ʻo Drager-Siemens IBP no ka transducer Medex/Abbott, B0403

    Medke P/N: B0403 Drager-Siemens IBP Adapter Hose, kūpono no ka Medex/Abbott transducer Latex free 3m TPU cable ʻEono mahina palapala CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Drager-Siemens Specifications Palekana: IEC 60101-1 apono 'ia, conformity me MDD 93/42/EEC a me AAMI/ANSI SP10 Ambient wela: 0 a 40°C(32 a hiki i 104°F) pili humidity: 15% a 95% Mea: Quality TPU jacket kaula;ʻO ka lāʻau lapaʻau PVC hoʻomaha;Nā pine gula a me...
  • Mindray-Datascope IBP Cable I Medex/Abbott Transducer, B0402

    Mindray-Datascope IBP Cable I Medex/Abbott Transducer, B0402

    Medke P/N: B0402 Mindray-Datascope IBP Adapter Hose, kūpono no ka Medex/Abbott transducer Latex free 3m TPU cable ʻEono mahina palapala CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Mindray-Datascope: System80, 82,86,84,90,90T,95,98,97IABP,850,870,P2,P3, 2000,2000a,2001,2001A,2002,2002A,Palapala Palapala Palekana Palekana: IEC 60101-4 MDD2 /EEC a me AAMI/ANSI SP10 Ka wela o ka puni: 0 a 40°C(32 a hiki i 104°F) Hahu pili...
  • AAMI/6P General IBP Cable To Medex/Abbott Transducer B0401

    AAMI/6P General IBP Cable To Medex/Abbott Transducer B0401

    Medke P/N: B0401 AAMI/6P Uea IBP maʻamau i ka transducer Medex/Abbott, hiki ke hoʻohana hou ʻia ka Latex manuahi 3m TPU kaula ʻeono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility BCI, IBY, Ctitikon, Invivo, Menen, Welch Allyn Abbott OEM: 42661-14 Nā ʻōlelo kikoʻī Palekana: IEC 60101-1 i ʻae ʻia, kūlike me MDD 93/42/EEC a me AAMI/ANSI SP10 Ka wela wela: 0 a 40 ° C (32 a 104 ° F) Pili humidity: 15% a i 95% Nā mea waiwai: TPU maikaʻi ...
  • Biolight IBP Cable I B.Bruan Transducer B0123

    Biolight IBP Cable I B.Bruan Transducer B0123

    Medke P/N: B0123 Biolight IBP Cable To B.Bruan Transducer Latex free 3m TPU cable Eono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Biolight Specifications Palekana: IEC 60101-1 apono ʻia, conformity me MDD 93/42/EEC a me AAMI/ANSI SP10 Ka wela wela: 0 a 40°C(32 a 104°F) Ka haʻahaʻa haʻahaʻa: 15% a hiki i 95% Nā mea waiwai: ʻO ke kaula TPU maikaʻi;ʻO ka lāʻau lapaʻau PVC hoʻomaha;Nā pine i uhi ʻia i ke gula a me nā plug Nylon Uku ʻia mākou ...
  • CSI IBP Cable I B.Bruan Transducer B0119

    CSI IBP Cable I B.Bruan Transducer B0119

    Medke P/N: B0119 CSI IBP Cable To B.Bruan Transducer Latex free 3m TPU cable ʻEono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility CSI Specifications Palekana: IEC 60101-1 apono ʻia, conformity me MDD 93/42/EEC a me AAMI/ANSI SP10 Ka wela wela: 0 a 40°C(32 a 104°F) Ka haʻahaʻa haʻahaʻa: 15% a hiki i 95% Nā mea waiwai: ʻO ke kaula TPU maikaʻi;ʻO ka lāʻau lapaʻau PVC hoʻomaha;Nā pine i uhi ʻia i ke gula a me nā plug Nylon Uku ʻae mākou i ka uku...
  • Mindray IBP Cable I B.Bruan Transducer, B0112

    Mindray IBP Cable I B.Bruan Transducer, B0112

    Medke P/N: B0112 Mindray IBP Adapter Hose, kūpono no ka B.Bruan transducer Latex free 3m TPU cable ʻEono mahina palapala hōʻoia CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Mindray: BeneView T5 BeneView T6 BeneView T8 MPM Specifications Palekana: IEC 60101-1 aponoia, conformity me MDD 93/42/EEC a me AAMI/ANSI SP10 Ambient wela: 0 i 40 ° C(32 a 104 ° F) pili humidity: 15% a 95% Mea: TPU maikaʻi kaula lole lole;Lapaʻau PVC stra...
  • Nihon Kohden IBP Cable To B.Bruan Transducer B0109

    Nihon Kohden IBP Cable To B.Bruan Transducer B0109

    Medke P/N: B0109 Nihon Kohden IBP uwea i B.Bruan transducer Latex free 3m TPU uwea Eono mahina palapala hoʻokō CE/ISO 13485 FSC FDA Pūʻulu: non-sterilization, pākahi pākahi me ke aʻo Compatibility Nihon Kohden: Lifescope 6,9,12, 14;AP-311P-800PA BMS 2100-8500A OEC 3200-8120A, OMP-3221E OMP-7203C, Mercury 9510K Nā kikoʻī Palekana: IEC 60101-1 i ʻae ʻia, kūlike me ka MDD 93/42/EEC a me ka mahana o ka AAMI00/42/EEC 40°C(32 a i 104°F) Ka haʻahaʻa haʻahaʻa: 15% a 95% Ma...