P9000VMulti-Para isigulana esweni
Iimpawu &IiNzuzo:
Iiparamitha eziqhelekileyo ze-5: ECG, RESP, NIBP, SPO2, 1-TEMP.
Uhlalutyo lwecandelo lexesha langempela le-ST, ukufumanisa isantya somenzi kunye nohlalutyo lwe-ARR.
Umboniso omninzi okhethiweyo obandakanya umgangatho, ifonti enkulu, i-trend coexis, i-OxyCRG eguquguqukayo
Uncedo lwe-intanethi kunye nolawulo lolwazi lwesigulana
Iifomu ezininzi ze-ECG ezikhokelayo ziboniswa kwisigaba.
Umthamo omkhulu wetheyibhile kunye nogcino lwemizobo yolwazi kwaye kulula ukuyikhumbula
Bamba iifom zamaza aguqukayo.
Ukuchasana ngokufanelekileyo nokuphazamiseka kwe-defibrillator kunye ne-HF knife.
Ukuya kuthi ga kwiiyure ezi-4 amandla okusebenza ebhetri eyakhelweyo egcwalisekayo.
Umthamo wothungelwano kunye neqonga lenethiwekhi ye-TCP/IP.
Ukhetho lwe-FHR, FM, TOCO, Printer, IBP kunye ne-EtCO2
Iinkcukacha Zokusebenza
Ukuqengqeleka kunye nokuhlaziya imbonakalo yamaza
Umboniso omninzi okhethekayo oquka:
Umboniso wefonti enkulu
Umboniso uhlala ukho
OxyCRG umboniso oguqukayo wokujonga.
Umboniso wokujonga ibhedi ukuya ebhedini
Umkhondo: i-9 waveforms (7 ECG, 1 SPO2 kunye ne-1 RESP)
Isantya sokutshayela: 12.5mm/s, 25mm/s, 50mm/s
Isalathisi: Ukukhanya kwesalathisi samandla/ibhetri
QRS beep kunye alarm isandi
Ibhetri: Iseli yeasidi etshajwayo kwakhona, 12v/4AH
Max.24 iyure ukutshaja, 4 iiyure ukuqhubeka ukusebenza
Umzila: Iparameter yegraphic kunye neendlela zetheyibhile:
5s/piece,8 iiyure;
1min/iqhekeza, iiyure eziyi-168(iyure ezingama-24×iintsuku ezisi-7)
5min/piece,1000 iiyure.
Ukugcinwa: I-NIBP: amaqela e-1000
I-alamu: amaqela angama-200
Ukubhengezwa okugcweleyo kweefom zamaza: 1 iyure
I-Alarm: Umsebenzisi-ohlengahlengiswayo oPhezulu, oPhakathi kunye noPhantsi imida yenqanaba le-3 elivakalayo kunye ne-alam ebonakalayo
Uthungelwano: Iqhagamshelwe kwinkqubo yokubeka iliso esembindini
TCP / IP inetha iqonga
IiParameters ezisemgangathweni
IECG:
Imowudi ekhokelayo: 5 –lead(R,L,F,N,C)
Ukukhetha inkokeli: I,II,III,avR,avL,avF,V
I-Waveform: i-3 kunye ne-7 channel ekhethiweyo
Ukufumana ukhetho: 0.5mm/mv,1mm/mv,2mm/mv
Isantya sokutshayela: 12.5mm/s; 25mm/s; 50mm/s
Uluhlu lwentliziyo:
Umntu omdala: 15 ~ 300bpm;
Umntwana osanda kuzalwa:/umntwana:15~350bpm
Ukuchaneka: +1bpm okanye +1%, yeyiphi enkulu
Isisombululo:1bpm
Isihluzo: imo yotyando: 1 ~ 20Hz
imodeli esweni: 0.5 ~ 40Hz
Indlela yokuxilonga: 0.05 ~ 130Hz
Umqondiso wokulinganisa: 1mv, +3%
Ukukhuselwa: ukumelana ne-4000VAC / 50 yokutshatyalaliswa kombane ngokuchasene nokuphazamiseka kwe-electrosurgical kunye nokuphelelwa amandla
Uluhlu lwe-alam: 15 ~ 350bpm
Isichongi secandelo le-ST:
Uluhlu lokulinganisa: 2.0mV ~ + 2.0mV
Uluhlu lweAlam: -2.0mV~ +2.0mV
Ukuchaneka: -0.8mV ~+0.8Mv
Imposiso: +0.02Mv
Uhlalutyo lweArrhythmia: EWE
SPO2
Uluhlu lomlinganiselo: 0 ~ 100%
Isisombululo: 1%
Ukuchaneka: + 2% (70-100%);0-69% engachazwanga
Uluhlu lwealam 0~100%
Ireyithi ye-Pluse: uluhlu: 20 ~ 300bpm
Isisombululo:1bpm
Imposiso:+1bpm okanye +2%, nokuba yeyiphi enkulu
I-NIBP
Indlela: Digital Automatic oscillometric
Imo yokusebenza : I-Manual/Automatic/continuous
Ixesha lokulinganisa okuzenzekelayo: Iyalungiseka (1 ~ 480min)
Iyunithi yoMlinganiso: mmHg/Kpa ekhethiweyo
Iindidi zokulinganisa: Systolic, Diastolic, Mean
Tange yomlinganiselo:
Uluhlu loxinzelelo lwe-Systolic:
Umntu omdala: 40-270mmHg
Unyango lwabantwana: 40 ~ 220mmHg
Umntwana osanda kuzalwa: 40 ~ 135mmHg
Uluhlu loxinzelelo oluphakathi:
Umntu omdala: 20 ~ 235mmHg
Unyango lwabantwana: 20 ~ 165mmHg
Umntwana osanda kuzalwa: 20-110mmHg
Uluhlu loxinzelelo lwe-diastolic:
Umntu omdala: 10 ~ 215mmHg
Unyango lwabantwana: 10 ~ 150mmHg
Umntwana osandul 'ukuzalwa :10-100mmHg
Ukhuseleko loxinzelelo olugqithisileyo:
Ukukhuselwa kabini kokhuseleko
Isisombululo: 1 mmHg
Ialam: Systolic.Diastolic,Mean
UKUPHEFUMLA
Indlela: Impedance ye-Thoracic
Uluhlu lokulinganisa: Umntu omdala: 7 ~ 120rpm;
Umntwana osandul 'ukuzalwa / abantwana: 7 ~ 150rpm
Apnea alarm: EWE, 10 ~ 40s
Isisombululo: 1rpm
Ukuchaneka: + 2rpm
UBUNGQONGQOSHE
Uphononongo oluhambelanayo: YSI okanye CYF
Uluhlu lomlinganiselo: 5 ~ 50℃
Isisombululo: 0.1℃
Ukuchaneka: +0.1℃
Ixesha lokuhlaziya: malunga ne-1
Ixesha eliphakathi lokulinganisa: <10s
FHR
Transducer: Multi-crystal, Pulsed Doppler
Uluhlu lokulinganisa: 50 ~ 210 BPM
Ukusebenza rhoqo: 1 MHz
Amandla: <5mW/cm2
Ukuqhubekeka koMqondiso:
inkqubo ekhethekileyo ye-DSP kunye nokuqondwa kwale mihla.
Isisombululo: 1BPM
Ukuchaneka: ±1BPM
Uluhlu lweAlarm: Phezulu: 160,170,180,190 BPM,
Phantsi: 100,110,120 BPM
FM
Ukumakishwa kweqhosha ngesandla,
ngokuzenzekelayo umsebenzi wokuchonga we-FM
Ukulinganisa kwe-TOCO
Transducer: Itransducer yoxinzelelo lwangaphandle
Uluhlu lomlinganiselo: 0 ~ 100 iiyunithi
Isisombululo: 1rpm
Ukuchaneka: ± 2 rpm
IBP
Ijelo: Iitshaneli ezi-2
Uluhlu: -50-300mmHg
Isisombululo: 1mmHg
Ukuchaneka: ±4mmHg(±4%)
Iyunithi: mmHg, Kpa
Isiguquli seSensitivity: 5mV/V/mmHg
Iindawo zeTransducer: ART/PA/CVP/LAP/RAP/ICP
EtCO2(I-Sidertream CO2)
Uluhlu lomlinganiselo: 0 ~ 99mmHg
Ukuchaneka: +2mmHg (0~40mmHg)
Uluhlu lweSampulu: 100ml / min
Ukuchaneka komlinganiselo wesampulu: 15%
Izinga lokuphefumla: 0 ~ 120rmp
Ukuchaneka kokuphefumla: +2rmp (0~70rmp)
+5rmp (>70rmp)
Ixesha lokuphefumula: <240msec (10% ukuya kwi-90%)
Ixesha lokulibazisa: <2s
EtCO2(umlambo CO2)
Indlela: Spectrum ye-infrared
Uluhlu: 0.0-10% (0~76%)
Isisombululo: 1mmHg (0.1%)
Ukuchaneka: <5%(±4.0 mmHg)
Okanye<10%(yeZifundo)
Umshicileli:
Yakha-ngaphakathi, i-thermal array
I-Plethysmogram caveform: iziteshi ezi-3
Imowudi yokurekhoda: i-manual, kwi-alarm, ixesha elichaziweyo
Ukurekhoda ububanzi: 50mm
Isantya sokushicilela: 50mm/s
Uhlobo lokurekhoda: Irekhodi yefomu engumkhenkce
Irekhodi ye-NIBP yokukhumbula
Ingxelo yetheyibhile ehamba phambili
Irekhodi ye-alam
Irekhodi yexesha elimiselweyo
Iintlobo ngeentlobo
Satety:
Inqanaba lokhuseleko: Udidi I, uhlobo CF
Idimendi kunye nobunzima
Umyinge: 440×430×450
G.Ubunzima: <9.0KS
Indawo yokusebenza
Ubushushu: Ukusebenza 0~+40℃
Ezothutho kunye nokugcinwa -20 ~ + 60℃
Ukufuma: ukusebenza≤85%
Ezothutho kunye nogcino≤93%
Amandla: AC 100-240,50/60Hz
Uluhlu lwezigulane:
Izigulana ezisandul' ukuzalwa, abantwana, kunye nabantu abadala
UmgangathoIzincedisi:
(1) 5 intambo ye-ECG ekhokelayo
(2) 1 spo2 probe
(3) 1 NIBP prbe
(4) 1 ixesha lokuvavanya
(5) I-1 yomgca wokudibanisa umhlaba
(6) I-electrode yesifuba (10pcs/iseti)